Logo

Vocabulary Reference

PerformanceParameter

enumeration

No description available.

URI:https://ref.openepcis.org/extensions/common/assessment/PerformanceParameter

Values (36)

ValueDescription
BatteryTemperature
Battery Temperature
Temperature of the battery under its operating environmental conditions, the latest reading outside an extreme-temperature excursion (unitCode CEL). Excursions are counted by eubat:TimeAboveTemperatureBoundary and its siblings.
CapacityFade
Capacity Fade
Capacity degradation as a percentage of the rated capacity, ((rated - remaining) / rated) x 100 (unitCode P1). Replaces eubat:hasCapacityFade.
CapacityThroughput
Capacity Throughput
Cumulative capacity throughput (unitCode AMH). Replaces eubat:hasCapacityThroughput.
ChargingTimeAboveTemperatureBoundary
Charging Time Above Temperature Boundary
Cumulative time the battery spent charging above the upper temperature boundary (unitCode MIN). Replaces eubat:timeSpentChargingDuringExtremeTemperaturesAboveBoundary.
ChargingTimeBelowTemperatureBoundary
Charging Time Below Temperature Boundary
Cumulative time the battery spent charging below the lower temperature boundary (unitCode MIN). Replaces eubat:timeSpentChargingDuringExtremeTemperaturesBelowBoundary.
CycleLife
Cycle Life
Number of full charge-discharge cycles the battery reaches in the cycle-life test until the exhaustion threshold (unitCode C62). Replaces eubat:expectedCycleLife.
DeepDischargeEvents
Deep Discharge Events
Cumulative count of deep-discharge events over the battery lifetime (unitCode C62). Replaces eubat:numberOfDeepDischargeEvents.
EnergyThroughput
Energy Throughput
Cumulative energy throughput (unitCode KWH). Replaces eubat:hasEnergyThroughput.
FullCycleCount
Full Cycle Count
Number of full charge-discharge cycles (unitCode C62). Replaces eubat:hasCycleCount.
InitialCapacity
Initial Capacity
Capacity measured at commissioning (unitCode AMH). Replaces eubat:hasInitialCapacity.
InitialCellInternalResistance
Initial Cell Internal Resistance
Internal resistance of the battery cell at the beginning of life (Annex XIII 1 (o)) (unitCode OHM). Replaces eubat:hasInitialCellInternalResistance.
InitialEnergy
Initial Energy
Energy measured at commissioning (unitCode KWH). Replaces eubat:hasInitialEnergy.
InitialPackInternalResistance
Initial Pack Internal Resistance
Internal resistance of the battery pack at the beginning of life (Annex XIII 1 (o)) (unitCode OHM). Replaces eubat:hasInitialPackInternalResistance.
InitialRoundTripEfficiency
Initial Round Trip Efficiency
Round-trip energy efficiency at the beginning of life (unitCode P1). Replaces eubat:roundTripEfficiency.
InitialSelfDischargeRate
Initial Self-Discharge Rate
Self-discharge rate at the beginning of life, in percent per month (unitCode P1). Replaces eubat:initialSelfDischarge.
InternalResistance
Internal Resistance
Current internal resistance of the battery (unitCode OHM). Replaces eubat:hasInternalResistance.
InternalResistanceIncrease
Internal Resistance Increase
Increase of the internal resistance over the initial value, in percent (unitCode P1). Replaces eubat:hasInternalResistanceIncrease.
LifetimeCapacityThroughput
Lifetime Capacity Throughput
Capacity throughput over the battery lifetime in the cycle-life test (unitCode AMH). Replaces eubat:hasExpectedLifetimeCapacityThroughput.
LifetimeEnergyThroughput
Lifetime Energy Throughput
Energy throughput over the battery lifetime in the cycle-life test (unitCode KWH). Replaces eubat:hasExpectedLifetimeEnergyThroughput.
MaximumVoltage
Maximum Voltage
Maximum Voltage measured within a temperature range, stated by the conditions eubat:LowerTemperatureBound and eubat:UpperTemperatureBound of its assessment (unitCode VLT).
MinimumVoltage
Minimum Voltage
Minimum Voltage measured within a temperature range, stated by the conditions eubat:LowerTemperatureBound and eubat:UpperTemperatureBound of its assessment (unitCode VLT).
NominalVoltage
Nominal Voltage
Nominal Voltage measured within a temperature range, stated by the conditions eubat:LowerTemperatureBound and eubat:UpperTemperatureBound of its assessment (unitCode VLT).
PowerCapability
Power Capability
Power capability at the state of charge the assessment states as its condition (eubat:StateOfChargeLevel); original in the performance test, remaining in the battery state (unitCode KWT). Replaces eubat:hasPowerCapability, eubat:hasRemainingPowerCapability, eubat:hasOriginalPowerCapability, eubat:hasPowerCapabilityAt80SoC, eubat:hasPowerCapabilityAt20SoC.
PowerFade
Power Fade
Power capability degradation as a percentage of the original power capability, ((original - remaining) / original) x 100 (unitCode P1). Replaces eubat:hasPowerFade.
RemainingCapacity
Remaining Capacity
Current maximum capacity (unitCode AMH). Replaces eubat:hasRemainingCapacity.
RemainingRoundTripEfficiency
Remaining Round Trip Efficiency
Current round-trip energy efficiency (unitCode P1). Replaces eubat:hasRemainingRoundTripEfficiency.
RemainingUsableEnergy
Remaining Usable Energy
Current remaining usable energy (unitCode KWH). Replaces eubat:hasRemainingUsableEnergy.
RoundTripEfficiencyAt50PercentCycleLife
Round Trip Efficiency at 50% Cycle Life
Round-trip energy efficiency at half of the cycle life (unitCode P1). Replaces eubat:roundTripEfficiencyAt50PercentCycleLife.
RoundTripEfficiencyFade
Round Trip Efficiency Fade
Degradation of the round-trip efficiency, ((initial - remaining) / initial) x 100 (unitCode P1). Replaces eubat:hasRoundTripEfficiencyFade.
SelfDischargeEvolution
Evolution of Self-Discharge
Change of the self-discharge rate against its initial value (unitCode P1). Replaces eubat:hasEvolutionOfSelfDischarge.
SelfDischargeRate
Self-Discharge Rate
Current self-discharge rate, in percent per month (unitCode P1). Replaces eubat:hasCurrentSelfDischargingRate.
StateOfCertifiedEnergy
State of Certified Energy
SOCE: remaining usable energy as a percentage of the certified usable energy (unitCode P1). Replaces eubat:hasStateOfCertifiedEnergy.
StateOfCharge
State of Charge
Charge level as a percentage of the current maximum capacity (unitCode P1). Replaces eubat:hasStateOfCharge.
StateOfHealth
State of Health
Battery state of health as a percentage of the original capacity (unitCode P1). Replaces eubat:hasStateOfHealth.
TimeAboveTemperatureBoundary
Time Above Temperature Boundary
Cumulative time the battery spent above the upper temperature boundary (unitCode MIN). Replaces eubat:timeSpentInExtremeTemperaturesAboveBoundary.
TimeBelowTemperatureBoundary
Time Below Temperature Boundary
Cumulative time the battery spent below the lower temperature boundary (unitCode MIN). Replaces eubat:timeSpentInExtremeTemperaturesBelowBoundary.