PerformanceParameter
enumerationNo description available.
Values (36)
| Value | Description |
|---|---|
| BatteryTemperature Battery Temperature | Temperature of the battery under its operating environmental conditions, the latest reading outside an extreme-temperature excursion (unitCode CEL). Excursions are counted by eubat:TimeAboveTemperatureBoundary and its siblings. |
| CapacityFade Capacity Fade | Capacity degradation as a percentage of the rated capacity, ((rated - remaining) / rated) x 100 (unitCode P1). Replaces eubat:hasCapacityFade. |
| CapacityThroughput Capacity Throughput | Cumulative capacity throughput (unitCode AMH). Replaces eubat:hasCapacityThroughput. |
| ChargingTimeAboveTemperatureBoundary Charging Time Above Temperature Boundary | Cumulative time the battery spent charging above the upper temperature boundary (unitCode MIN). Replaces eubat:timeSpentChargingDuringExtremeTemperaturesAboveBoundary. |
| ChargingTimeBelowTemperatureBoundary Charging Time Below Temperature Boundary | Cumulative time the battery spent charging below the lower temperature boundary (unitCode MIN). Replaces eubat:timeSpentChargingDuringExtremeTemperaturesBelowBoundary. |
| CycleLife Cycle Life | Number of full charge-discharge cycles the battery reaches in the cycle-life test until the exhaustion threshold (unitCode C62). Replaces eubat:expectedCycleLife. |
| DeepDischargeEvents Deep Discharge Events | Cumulative count of deep-discharge events over the battery lifetime (unitCode C62). Replaces eubat:numberOfDeepDischargeEvents. |
| EnergyThroughput Energy Throughput | Cumulative energy throughput (unitCode KWH). Replaces eubat:hasEnergyThroughput. |
| FullCycleCount Full Cycle Count | Number of full charge-discharge cycles (unitCode C62). Replaces eubat:hasCycleCount. |
| InitialCapacity Initial Capacity | Capacity measured at commissioning (unitCode AMH). Replaces eubat:hasInitialCapacity. |
| InitialCellInternalResistance Initial Cell Internal Resistance | Internal resistance of the battery cell at the beginning of life (Annex XIII 1 (o)) (unitCode OHM). Replaces eubat:hasInitialCellInternalResistance. |
| InitialEnergy Initial Energy | Energy measured at commissioning (unitCode KWH). Replaces eubat:hasInitialEnergy. |
| InitialPackInternalResistance Initial Pack Internal Resistance | Internal resistance of the battery pack at the beginning of life (Annex XIII 1 (o)) (unitCode OHM). Replaces eubat:hasInitialPackInternalResistance. |
| InitialRoundTripEfficiency Initial Round Trip Efficiency | Round-trip energy efficiency at the beginning of life (unitCode P1). Replaces eubat:roundTripEfficiency. |
| InitialSelfDischargeRate Initial Self-Discharge Rate | Self-discharge rate at the beginning of life, in percent per month (unitCode P1). Replaces eubat:initialSelfDischarge. |
| InternalResistance Internal Resistance | Current internal resistance of the battery (unitCode OHM). Replaces eubat:hasInternalResistance. |
| InternalResistanceIncrease Internal Resistance Increase | Increase of the internal resistance over the initial value, in percent (unitCode P1). Replaces eubat:hasInternalResistanceIncrease. |
| LifetimeCapacityThroughput Lifetime Capacity Throughput | Capacity throughput over the battery lifetime in the cycle-life test (unitCode AMH). Replaces eubat:hasExpectedLifetimeCapacityThroughput. |
| LifetimeEnergyThroughput Lifetime Energy Throughput | Energy throughput over the battery lifetime in the cycle-life test (unitCode KWH). Replaces eubat:hasExpectedLifetimeEnergyThroughput. |
| MaximumVoltage Maximum Voltage | Maximum Voltage measured within a temperature range, stated by the conditions eubat:LowerTemperatureBound and eubat:UpperTemperatureBound of its assessment (unitCode VLT). |
| MinimumVoltage Minimum Voltage | Minimum Voltage measured within a temperature range, stated by the conditions eubat:LowerTemperatureBound and eubat:UpperTemperatureBound of its assessment (unitCode VLT). |
| NominalVoltage Nominal Voltage | Nominal Voltage measured within a temperature range, stated by the conditions eubat:LowerTemperatureBound and eubat:UpperTemperatureBound of its assessment (unitCode VLT). |
| PowerCapability Power Capability | Power capability at the state of charge the assessment states as its condition (eubat:StateOfChargeLevel); original in the performance test, remaining in the battery state (unitCode KWT). Replaces eubat:hasPowerCapability, eubat:hasRemainingPowerCapability, eubat:hasOriginalPowerCapability, eubat:hasPowerCapabilityAt80SoC, eubat:hasPowerCapabilityAt20SoC. |
| PowerFade Power Fade | Power capability degradation as a percentage of the original power capability, ((original - remaining) / original) x 100 (unitCode P1). Replaces eubat:hasPowerFade. |
| RemainingCapacity Remaining Capacity | Current maximum capacity (unitCode AMH). Replaces eubat:hasRemainingCapacity. |
| RemainingRoundTripEfficiency Remaining Round Trip Efficiency | Current round-trip energy efficiency (unitCode P1). Replaces eubat:hasRemainingRoundTripEfficiency. |
| RemainingUsableEnergy Remaining Usable Energy | Current remaining usable energy (unitCode KWH). Replaces eubat:hasRemainingUsableEnergy. |
| RoundTripEfficiencyAt50PercentCycleLife Round Trip Efficiency at 50% Cycle Life | Round-trip energy efficiency at half of the cycle life (unitCode P1). Replaces eubat:roundTripEfficiencyAt50PercentCycleLife. |
| RoundTripEfficiencyFade Round Trip Efficiency Fade | Degradation of the round-trip efficiency, ((initial - remaining) / initial) x 100 (unitCode P1). Replaces eubat:hasRoundTripEfficiencyFade. |
| SelfDischargeEvolution Evolution of Self-Discharge | Change of the self-discharge rate against its initial value (unitCode P1). Replaces eubat:hasEvolutionOfSelfDischarge. |
| SelfDischargeRate Self-Discharge Rate | Current self-discharge rate, in percent per month (unitCode P1). Replaces eubat:hasCurrentSelfDischargingRate. |
| StateOfCertifiedEnergy State of Certified Energy | SOCE: remaining usable energy as a percentage of the certified usable energy (unitCode P1). Replaces eubat:hasStateOfCertifiedEnergy. |
| StateOfCharge State of Charge | Charge level as a percentage of the current maximum capacity (unitCode P1). Replaces eubat:hasStateOfCharge. |
| StateOfHealth State of Health | Battery state of health as a percentage of the original capacity (unitCode P1). Replaces eubat:hasStateOfHealth. |
| TimeAboveTemperatureBoundary Time Above Temperature Boundary | Cumulative time the battery spent above the upper temperature boundary (unitCode MIN). Replaces eubat:timeSpentInExtremeTemperaturesAboveBoundary. |
| TimeBelowTemperatureBoundary Time Below Temperature Boundary | Cumulative time the battery spent below the lower temperature boundary (unitCode MIN). Replaces eubat:timeSpentInExtremeTemperaturesBelowBoundary. |