Logo

Vocabulary Reference

TechnicalSpecification

class

Technical Specification

Technical specifications of a battery including capacity, voltage, and performance parameters.

URI:https://ref.openepcis.org/extensions/eu/battery/TechnicalSpecification

Upstream alignment

How this class and its properties align to external and upstream vocabularies. Open a vocabulary to see the exact term-by-term relationships.

Properties (19)

DescriptionDomainRangeVocabularies
cRate
C-Rate
Nominal charge/discharge rate relative to capacity (e.g., 1C = full charge in 1 hour).eubat:TechnicalSpecificationxsd:decimal Public
hasExpectedLifetime
Expected Lifetime
Expected lifetime of the battery in calendar years under the reference conditions it was designed for. Use gs1:QuantitativeValue with unitCode 'ANN' (years) per UN/CEFACT Rec 20.eubat:TechnicalSpecificationgs1:QuantitativeValue Public
hasMaximumChargingCurrent
Maximum Charging Current
Maximum allowed charging current in Amperes. Use unitCode 'AMP' (UN/CEFACT Rec 20).eubat:TechnicalSpecificationgs1:QuantitativeValue Public—
hasMaximumChargingPower
Maximum Charging Power
Maximum allowed charging power in kW. Use unitCode 'KWT' (UN/CEFACT Rec 20).eubat:TechnicalSpecificationgs1:QuantitativeValue Public
hasMaximumDischargingCurrent
Maximum Discharging Current
Maximum allowed discharging current in Amperes. Use unitCode 'AMP' (UN/CEFACT Rec 20).eubat:TechnicalSpecificationgs1:QuantitativeValue Public—
hasMaximumDischargingPower
Maximum Discharging Power
Maximum allowed discharging power in kW. Use unitCode 'KWT' (UN/CEFACT Rec 20).eubat:TechnicalSpecificationgs1:QuantitativeValue Public
hasMaximumPermittedBatteryPower
Maximum Permitted Battery Power
Maximum permitted battery power (single declared value). Use gs1:QuantitativeValue with unitCode 'WTT' (watt) or 'KWT' (kW), UN/CEFACT Rec 20.eubat:TechnicalSpecificationgs1:QuantitativeValue Public
hasMaximumVoltage
Maximum Voltage
Maximum allowable voltage when fully charged, in Volts (V). Use unitCode 'VLT' (UN/CEFACT Rec 20).eubat:TechnicalSpecificationgs1:QuantitativeValue Public
hasMinimumVoltage
Minimum Voltage
Minimum allowable voltage to prevent deep discharge damage, in Volts (V). Use unitCode 'VLT' (UN/CEFACT Rec 20).eubat:TechnicalSpecificationgs1:QuantitativeValue Public
hasNominalVoltage
Nominal Voltage
Nominal operating voltage of the battery pack in Volts (V). Use unitCode 'VLT' (UN/CEFACT Rec 20).eubat:TechnicalSpecificationgs1:QuantitativeValue Public
hasPerformanceTest
Performance and Durability Test
The performance and durability tests behind the declared technical specification.eubat:TechnicalSpecificationeubat:PerformanceDurabilityTest Public—
hasRatedCapacity
Rated Capacity
Rated capacity in Ampere-hours (Ah). Use gs1:QuantitativeValue with unitCode 'AMH'.eubat:TechnicalSpecificationgs1:QuantitativeValue Public
hasRatedEnergy
Rated Energy
Rated energy in kilowatt-hours (kWh). Use gs1:QuantitativeValue with unitCode 'KWH'.eubat:TechnicalSpecificationgs1:QuantitativeValue Public
hasRatedMaximumPower
Rated Maximum Power
Rated maximum power output in kW. Use unitCode 'KWT' (UN/CEFACT Rec 20).eubat:TechnicalSpecificationgs1:QuantitativeValue Public—
hasTemperatureRangeCharging
Temperature Range - Charging
Allowable temperature range during charging.eubat:TechnicalSpecificationeubat:TemperatureRange Public—
hasTemperatureRangeDischarging
Temperature Range - Discharging
Allowable temperature range during discharging.eubat:TechnicalSpecificationeubat:TemperatureRange Public—
hasTemperatureRangeIdleState
Temperature Range - Idle State
Temperature range for the battery in idle state.eubat:TechnicalSpecificationeubat:TemperatureRange Public
hasTemperatureRangeStorage
Temperature Range - Storage
Allowable temperature range for battery storage.eubat:TechnicalSpecificationeubat:TemperatureRange Public
powerCapabilityRatio
Power Capability Ratio
Ratio of rated power to rated energy (W/Wh).eubat:TechnicalSpecificationxsd:decimal Public

Vocabulary alignment

Used as Range (1)

JSON-LD Example

{
  "@context": "https://ref.openepcis.org/extensions/eu/battery/battery-context.jsonld",
  "type": "TechnicalSpecification",
  "cRate": "...",
  "hasExpectedLifetime": "...",
  "hasMaximumChargingCurrent": "..."
}