TechnicalSpecification
classTechnical Specification
Technical specifications of a battery including capacity, voltage, and performance parameters.
Upstream alignment
How this class and its properties align to external and upstream vocabularies. Open a vocabulary to see the exact term-by-term relationships.
Properties (19)
| Description | Domain | Range | Vocabularies | ||
|---|---|---|---|---|---|
| cRate C-Rate | Nominal charge/discharge rate relative to capacity (e.g., 1C = full charge in 1 hour). | eubat:TechnicalSpecification | xsd:decimal | Public | |
| hasExpectedLifetime Expected Lifetime | Expected lifetime of the battery in calendar years under the reference conditions it was designed for. Use gs1:QuantitativeValue with unitCode 'ANN' (years) per UN/CEFACT Rec 20. | eubat:TechnicalSpecification | gs1:QuantitativeValue | Public | |
| hasMaximumChargingCurrent Maximum Charging Current | Maximum allowed charging current in Amperes. Use unitCode 'AMP' (UN/CEFACT Rec 20). | eubat:TechnicalSpecification | gs1:QuantitativeValue | Public | — |
| hasMaximumChargingPower Maximum Charging Power | Maximum allowed charging power in kW. Use unitCode 'KWT' (UN/CEFACT Rec 20). | eubat:TechnicalSpecification | gs1:QuantitativeValue | Public | |
| hasMaximumDischargingCurrent Maximum Discharging Current | Maximum allowed discharging current in Amperes. Use unitCode 'AMP' (UN/CEFACT Rec 20). | eubat:TechnicalSpecification | gs1:QuantitativeValue | Public | — |
| hasMaximumDischargingPower Maximum Discharging Power | Maximum allowed discharging power in kW. Use unitCode 'KWT' (UN/CEFACT Rec 20). | eubat:TechnicalSpecification | gs1:QuantitativeValue | Public | |
| hasMaximumPermittedBatteryPower Maximum Permitted Battery Power | Maximum permitted battery power (single declared value). Use gs1:QuantitativeValue with unitCode 'WTT' (watt) or 'KWT' (kW), UN/CEFACT Rec 20. | eubat:TechnicalSpecification | gs1:QuantitativeValue | Public | |
| hasMaximumVoltage Maximum Voltage | Maximum allowable voltage when fully charged, in Volts (V). Use unitCode 'VLT' (UN/CEFACT Rec 20). | eubat:TechnicalSpecification | gs1:QuantitativeValue | Public | |
| hasMinimumVoltage Minimum Voltage | Minimum allowable voltage to prevent deep discharge damage, in Volts (V). Use unitCode 'VLT' (UN/CEFACT Rec 20). | eubat:TechnicalSpecification | gs1:QuantitativeValue | Public | |
| hasNominalVoltage Nominal Voltage | Nominal operating voltage of the battery pack in Volts (V). Use unitCode 'VLT' (UN/CEFACT Rec 20). | eubat:TechnicalSpecification | gs1:QuantitativeValue | Public | |
| hasPerformanceTest Performance and Durability Test | The performance and durability tests behind the declared technical specification. | eubat:TechnicalSpecification | eubat:PerformanceDurabilityTest | Public | — |
| hasRatedCapacity Rated Capacity | Rated capacity in Ampere-hours (Ah). Use gs1:QuantitativeValue with unitCode 'AMH'. | eubat:TechnicalSpecification | gs1:QuantitativeValue | Public | |
| hasRatedEnergy Rated Energy | Rated energy in kilowatt-hours (kWh). Use gs1:QuantitativeValue with unitCode 'KWH'. | eubat:TechnicalSpecification | gs1:QuantitativeValue | Public | |
| hasRatedMaximumPower Rated Maximum Power | Rated maximum power output in kW. Use unitCode 'KWT' (UN/CEFACT Rec 20). | eubat:TechnicalSpecification | gs1:QuantitativeValue | Public | — |
| hasTemperatureRangeCharging Temperature Range - Charging | Allowable temperature range during charging. | eubat:TechnicalSpecification | eubat:TemperatureRange | Public | — |
| hasTemperatureRangeDischarging Temperature Range - Discharging | Allowable temperature range during discharging. | eubat:TechnicalSpecification | eubat:TemperatureRange | Public | — |
| hasTemperatureRangeIdleState Temperature Range - Idle State | Temperature range for the battery in idle state. | eubat:TechnicalSpecification | eubat:TemperatureRange | Public | |
| hasTemperatureRangeStorage Temperature Range - Storage | Allowable temperature range for battery storage. | eubat:TechnicalSpecification | eubat:TemperatureRange | Public | |
| powerCapabilityRatio Power Capability Ratio | Ratio of rated power to rated energy (W/Wh). | eubat:TechnicalSpecification | xsd:decimal | Public |
Vocabulary alignment
Broader · upstream
Used as Range (1)
Where used
Referenced by other terms (20)
domain:
eu/batterycRateeu/batteryhasExpectedLifetimeeu/batteryhasMaximumChargingCurrenteu/batteryhasMaximumChargingPowereu/batteryhasMaximumDischargingCurrenteu/batteryhasMaximumDischargingPowereu/batteryhasMaximumPermittedBatteryPowereu/batteryhasMaximumVoltageeu/batteryhasMinimumVoltageeu/batteryhasNominalVoltageeu/batteryhasPerformanceTesteu/batteryhasRatedCapacityeu/batteryhasRatedEnergyeu/batteryhasRatedMaximumPowereu/batteryhasTemperatureRangeChargingeu/batteryhasTemperatureRangeDischargingeu/batteryhasTemperatureRangeIdleStateeu/batteryhasTemperatureRangeStorageeu/batterypowerCapabilityRatio
In SHACL shapes (2)
- TechnicalSpecificationShapetargets
- BatteryShapeclass-of
In example documents (11)
Master data & product examples
- amperia-staxwall-model.jsonld
- amperia-staxwall-model.operational.jsonld
- battery-product-model.jsonld
- battery-product-model.operational.jsonld
- battery-product.jsonld
- battery-product.operational.jsonld
- batterypass-ev-item.jsonld
- batterypass-industrial-item.jsonld
- batterypass-lmt-item.jsonld
- portable-ebike-battery.jsonld
- portable-ebike-battery.operational.jsonld
References
JSON-LD Example
{
"@context": "https://ref.openepcis.org/extensions/eu/battery/battery-context.jsonld",
"type": "TechnicalSpecification",
"cRate": "...",
"hasExpectedLifetime": "...",
"hasMaximumChargingCurrent": "..."
}